What tests are required to list a self-ballasted fluorescent or high intensity discharge (HID) GU24 lamp on the Certified Lighting Subcomponent Database (CSD), so that it can be used to qualify a product to the Luminaires specification?

To list a self-ballasted fluorescent or high intensity discharge (HID) GU24 lamp on the Certified Lighting Subcomponent Database (CSD), data must be submitted to a certification body (CB) demonstrating the lamp’s compliance with the following specification requirements:

  • Luminous Efficacy

  • Total lumen output

  • Light Source Life

  • Lumen Maintenance

  • Correlated Color Temperature (Indoor and Indoor/Outdoor only)

  • Color Rendering (Indoor and Indoor/Outdoor only)

  • Source Start Time (Indoor and Indoor/Outdoor only)

  • Source Run up time (Indoor and Indoor/Outdoor only)

  • Dimming (as applicable)

  • Power Factor

  • Transient Protection

  • Operating Frequency

  • Minimum operating temperature (Indoor and Indoor/Outdoor only)

  • Maximum Recommended Ballast Case Temperature

  • Ballast Hot Spot Location

Was this answer helpful?YesNo
Topic Information
  • Topic #: 23002-33326
  • Date Created: 3/30/2012
  • Last Modified Since: 4/18/2014
  • Viewed: 3618
Welcome Guest