What tests are required to list an LED light engine on the Certified Lighting Subcomponent Database (CSD), so that it can be used to qualify a product to the Luminaires specification?

To list an LED light engine on the Certified Lighting Subcomponent Database (CSD), data must be submitted to a certification body (CB) demonstrating the engine‚Äôs compliance with the following specification requirements: 

  • Luminous Efficacy

  • Lumen Output

  • Lumen Maintenance

  • Correlated Color Temperature (Indoor and Indoor/Outdoor only)

  • Color Rendering (Indoor and Indoor/Outdoor only)

  • Color Maintenance (Indoor and Indoor/Outdoor only)

  • Maximum In-Situ Operating Temperature at Tb to meet ENERGY STAR specifications based on LM-82-12 results

  • Source Start Time (Indoor and Indoor/Outdoor only)

  • Source Run-Up Time (Indoor and Indoor/Outdoor only)

  • Dimming (as applicable)

  • Power Factor

  • Transient Protection

  • Operating Frequency

  • Maximum Recommended Driver Case Temperature

  • Temperature Measurement Point on the Driver Case (TMPd)

  • Minimum Operating Temperature (Outdoor and Indoor/Outdoor only)

  • Driver Safety

Was this answer helpful?YesNo
Topic Information
  • Topic #: 23002-33322
  • Date Created: 3/30/2012
  • Last Modified Since: 4/18/2014
  • Viewed: 4233
Welcome Guest